Protect your property’s drinking water, satisfy municipal plumbing codes, and pass initial cross-connection inspections with DPOR-certified Master Plumbers. Family-owned and trusted across Northern Virginia since 1928.
Speak Directly with a Master Plumber:
Every building connected to municipal water lines in Northern Virginia shares a pressurized distribution system. When an unexpected drop in municipal water pressure occurs (caused by water main breaks, scheduled line flushing, or heavy municipal fire department water usage), a reverse hydraulic vacuum pulls stagnant or contaminated water from your property back into clean drinking lines. This dangerous dynamic is known as back-siphonage.
In other facilities, downstream equipment like pressurized boilers, irrigation pumps, or chemical dispensers generate pressure higher than incoming city mains.Â
This creates back-pressure, forcing contaminated fluids backward through open supply connections.
Under the Virginia Department of Health Waterworks Regulations (12VAC5-590-630) and Fairfax County Land Development Services cross-connection guidelines, installing an approved backflow preventer is a mandatory legal safeguard for high-hazard and moderate-hazard water fixtures.
Installing a backflow assembly is never a weekend do-it-yourself project. An improperly positioned valve can freeze and rupture during mid-Atlantic winters, discharge gallons of water onto structural drywall, or fail municipal inspection immediately upon activation.Â
At Backflow Services Done Right (operated by Baumbach Plumbing and Remodeling, Virginia Class A Contractor License #2705041764), our Master Plumbers engineer code-compliant, properly sized installations that keep your water safe and your property fully compliant from day one.
Different plumbing applications require distinct hazard containment ratings. Our experienced technicians evaluate your plumbing layout, incoming water pressure, and chemical exposure risks to install the precise device specified by local water purveyors:
The highest level of mechanical protection available. RPZ assemblies utilize two independent, spring-loaded check valves separated by an automatic, differential pressure-relief valve. RPZs are mandated on high-hazard commercial connections, industrial cooling towers, commercial boilers, and irrigation setups with dedicated chemical injectors. Explore our detailed guide on RPZ valve installation in Northern Virginia to see whether your building requires this assembly.

Designed for low-to-medium hazard installations where continuous pressure exists but no toxic substances are handled. DCVs consist of two tight-seating check valves within a single body. They are common in commercial fire sprinkler lines and indoor domestic separation loops.

The regional industry standard for residential lawn sprinkler systems and landscape irrigation. PVBs feature an independently operating internal check valve and an atmospheric vent that breaks siphon vacuums instantly when supply line pressure drops.

Physical air separations and point-of-use fixtures installed directly on dedicated industrial sinks, commercial dishwashers, and laboratory sinks.
Already have a valve installed that is dripping continuously or failed an annual inspection? Review our backflow repair and diagnostic services to see if a cost-effective rebuild kit can restore your assembly without a complete replacement.
We deliver complete project management from initial engineering assessment through official county inspection sign-off:

Our licensed Master Plumber inspects your incoming water service line, measures operating pressure, and evaluates potential backflow risks. We identify the exact assembly type required by your municipal water purveyor (Fairfax Water, Arlington County, AlexRenew, or Loudoun Water).

Proper hydraulic sizing prevents disruptive water pressure drops throughout your building. We map required clearances, configure required relief-valve drainage pathways, and handle all plumbing permit applications directly through your local building jurisdiction.

Our technicians plumb the assembly into your water line using high-grade lead-free bronze, ductile iron, or stainless steel assemblies from leading manufacturers like Watts, Zurn-Wilkins, Apollo, and Febco. We install full-port isolation ball valves, upstream strainers, unions for straightforward future servicing, and code-approved drain piping.

Virginia law dictates that every newly installed or replaced backflow prevention assembly must undergo certified testing before being approved for active water service. We hook up calibrated differential pressure gauges to verify that each check valve and relief valve operates within exact statutory tolerances.

We document all diagnostic readings on official state test forms, apply physical certification tags to the device body, and file the passing report directly with your regional water authority to close out all open permits.
Installation costs vary depending on valve type, pipe diameter, indoor versus outdoor placement, and excavation requirements. We provide upfront, transparent pricing before turning a single wrench. For detailed budgeting insight, review our comprehensive guide on backflow preventer installation costs in Virginia.
| Property & Assembly Configuration | Typical Pipe Sizes | Average Installed Cost Range | What the Service Package Includes |
|---|---|---|---|
| Residential Lawn Sprinkler (PVB) | 3/4" to 1" | $350 - $750 | Assembly, copper tie-in, isolation valves, testing, county filing |
| Residential / Light Commercial (DCV) | 3/4" to 1-1/2" | $550 - $1,200 | Double check valve, indoor or vault plumbing, initial test, permit |
| Commercial RPZ Valve Retrofit | 3/4" to 2" | $1,100 - $2,600 | High-hazard RPZ unit, copper/brass piping, air-gap drain, certification |
| Large Commercial & Multi-Family RPZ | 2-1/2" to 4"+ | $2,800 - $6,500+ | Flanged assembly, bypass loop, drainage plumbing, utility inspection |
| Commercial Fire Suppression Line | 4" to 8"+ | $4,200 - $9,500+ | Double detector check assembly, OS&Y valves, flow tests, fire filing |
| Direct Valve Replacement (Like-for-Like) | 3/4" to 1-1/2" | $325 - $650 | Unbolt failing valve, install identical body, test, update records |
Seamless Sprinkler Backflow Replacement in Fairfax
“Our home’s old lawn irrigation backflow valve cracked after an early November freeze. Backflow Services Done Right gave us an upfront quote over the phone, arrived the next day, and replaced the unit with a heavy-duty Wilkins PVB. The technician tested the system on the spot and filed the report directly with Fairfax County. Clean, professional, and zero stress.”
Homeowner in Fairfax, VA
Emergency RPZ Replacement for Our Commercial Kitchen
“A catastrophic leak on our restaurant’s commercial boiler RPZ threatened to shut down our weekend service in Arlington. Their Master Plumber arrived within hours, sourced the exact Watts replacement valve from their supplier, and repiped the drainage line to code. They saved our business thousands in lost revenue and took care of all county paperwork.”
Restaurant Owner in Arlington, VA
Flawless HOA Pool House Installation
“We needed a new backflow preventer installed for our community pool house in Reston to satisfy updated Loudoun Water safety requirements. Backflow Services Done Right handled everything: pulling the county permits, installing a high-hazard RPZ assembly with proper winter shutoffs, and completing the initial certification test. Excellent communication with our board.”
HOA Facilities Director in Reston, VA
Plumbing codes and backflow installation standards differ based on your local utility:

Requires dedicated permits for new cross-connection installations. RPZ assemblies must be installed above finished floor level with adequate gravity drainage to the exterior or a floor drain capable of handling maximum discharge rates. Review our Fairfax County backflow testing and installation guide for local regulatory nuances.

Requires backflow assemblies to be installed in accessible locations with 12 to 30 inches of side clearance for maintenance and annual re-testing. See our Arlington backflow services page for commercial specifications.

Enforces strict backflow containment standards on historical structures and renovations. Explore our Alexandria backflow services page for municipal guidelines.

Commercial properties, breweries, multi-family facilities, and private schools must adhere to local utility cross-connection mandates and schedule verified initial acceptance testing before building occupancy approval.
In Northern Virginia jurisdictions, do-it-yourself installation of testable backflow assemblies is generally prohibited. The Virginia Uniform Statewide Building Code requires plumbing permits pulled by a licensed contractor. Furthermore, the installation is not legally recognized until an initial acceptance test is performed and signed by a DPOR-certified Backflow Prevention Assembly Tester.
A direct, like-for-like residential replacement usually takes 1 to 2 hours. A brand-new installation requiring new pipe routing, shutoff valve integration, and exterior wall penetrations typically takes 3 to 5 hours. Large commercial installations or retrofits involving flanged pipe sections and vault modifications may require a full working day.
Yes. At Backflow Services Done Right, our installation estimates include the physical assembly, all installation fittings, isolation valves, the required initial differential pressure test, and direct compliance filing with your local water authority. Ongoing compliance requires annual certified backflow testing, which we can schedule automatically for future years.
Under plumbing code requirements, Pressure Vacuum Breakers (PVBs) must be installed at least 12 inches above the highest downstream sprinkler head or emission point on the property. RPZ valves must be installed at least 12 inches above ground grade or floor level to allow the differential relief valve to discharge freely without the risk of submergence.
Outdoor backflow assemblies must be winterized before the first hard freeze in Northern Virginia. This involves shutting off the interior isolation valve, opening the test cocks to a 45-degree angle, draining all residual water, and wrapping the valve in an insulated marine-grade thermal enclosure.
Ensure your home or commercial building meets all Virginia health regulations with precision plumbing from Master Plumbers who know Northern Virginia codes inside and out.
(703) 250-4200
(703) 524-1250
11608 Fairfax Station Rd, Fairfax Station, VA 22039
Providing reliable, code-compliant backflow installation services for homes and businesses across Northern Virginia.