Protect your drinking water, maintain county compliance, and eliminate utility shutoff notices with DPOR-certified Master Plumbers. Family-owned and operated since 1928.
Call Our Local Specialists:
Every public drinking system in Northern Virginia relies on continuous forward water pressure. However, unexpected hydraulic shocks (such as water main ruptures, municipal line flushing, or heavy water draw during local firefighting operations) drop street pressure rapidly.
This drop causes back-siphonage, pulling water backward from private plumbing into the public mains. In other scenarios, pressurized equipment like commercial boilers, landscape chemical injectors, or irrigation boosters generate back-pressure, forcing stagnant water back into clean supply lines.
To prevent widespread contamination, the Virginia Department of Health Waterworks Regulations (12VAC5-590-630) mandates that every community waterworks operate a strict Cross-Connection Control Program. Under this regulatory standard and guidance from the U.S. EPA Cross-Connection Control Manual, water purveyors require certified annual testing for all testable mechanical assemblies.
Because backflow preventers contain internal springs, diaphragms, and rubber check discs that deteriorate over time from water friction, mineral deposits, and winter freezing, physical testing is the only way to confirm internal valve operation.
At Backflow Services Done Right (operated by Baumbach Plumbing and Remodeling), we eliminate the hassle of regulatory compliance. As an authorized vendor holding Virginia Class A Contractor License #2705041764, we conduct precise diagnostic tests and submit passing reports directly to your local water purveyor.
Different plumbing cross-connections carry varying hazard levels. Our technicians carry specialized differential pressure test gauges to inspect every assembly type approved in Virginia:

Required for high-hazard connections where chemical, industrial, or toxic pollutants are present. RPZs feature two independent check valves and an automatic differential pressure relief valve that vents water to the atmosphere if an internal seal fails.

Designed for low-to-medium hazard applications such as non-chemical fire sprinkler systems and select indoor commercial loops. DCVs use two sequential spring-loaded check valves to block reverse flow.

The standard safety installation for residential lawn irrigation and commercial sprinkler systems, preventing backsiphonage when the system shuts down.

Non-testable physical air separations and point-of-use fixtures inspected during full-facility backflow surveys.
Need a replacement valve or a brand-new setup? Explore our backflow preventer installation services to review code-compliant options for your property.
We follow standardized American Society of Sanitary Engineering (ASSE) field testing protocols to inspect your equipment quickly and accurately without causing disruption to your daily routine:

The technician identifies the make, model, size, and serial number of your backflow preventer. We verify that the assembly is installed with proper clearances, accessible test cocks, and adequate drainage.

We shut off flow through the device using the upstream and downstream shutoff valves. A field-calibrated differential pressure gauge is attached to the integrated test cocks to isolate internal chambers.

Our certified tester tests each check valve independently to verify it holds tight against backward pressure at or above required minimums (typically 1.0 to 5.0 PSI). On RPZ units, we measure the exact opening threshold of the differential relief valve to guarantee fail-safe discharge.

If the device passes, we log the numerical data immediately. If internal rubber discs or springs fail to seat due to mineral scale or physical wear, our fully stocked service trucks carry OEM parts to perform immediate repairs. Review our backflow repair and diagnostic services for comprehensive rebuild details.

You receive a completed digital copy for your property files. Our team handles official filing directly with Fairfax County Land Development Services, Fairfax Water, Arlington County, or AlexRenew, keeping your compliance record clear.
We believe in upfront, transparent pricing without hidden trip charges or filing fees. Below are our standard rates across Northern Virginia. For a comprehensive overview, review our guide to backflow testing costs in Northern Virginia.
| Property and Assembly Type | Typical Valve Sizes | Standard Testing Fee | Included Compliance Services |
|---|---|---|---|
| Residential Lawn Sprinkler (PVB / DCV) | 3/4" to 1" | $85 - $145 | Precision test, full inspection record, direct county submission |
| Commercial Retail & Restaurant (RPZ / DCV) | 3/4" to 2" | $125 - $195 | Certified test, shutoff validation, utility report filing, site tag |
| HOA Common Lines & Mid-Size Commercial | 2-1/2" to 3" | $175 - $275 | Vault access, differential pressure test, compliance portal logging |
| Large Industrial & Commercial Fire Lines | 4" to 8"+ | $250 - $450+ | Double detector testing, flow evaluation, water authority reporting |
| Multi-Device Commercial Portfolios | Any Configuration | 10% to 25% Off | Volume discounts applied for multiple valves tested in one visit |
| Diagnostic Re-Test (After Part Rebuild) | All Sizes | $50 - $75 | Post-repair certification to clear open violation notices |
A failed inspection does not always indicate a ruined assembly. Most failed tests are caused by tiny pebbles, pipe scale, or hardened rubber seals preventing a check valve from closing firmly.
Local jurisdictions in Northern Virginia, including Fairfax County and Arlington, enforce a strict 10-business-day correction window after a failed test. Property owners must complete repairs and pass a certified re-test within this timeframe to prevent water service shutoff notices or municipal fines.
Because our technicians carry OEM rebuild kits from leading manufacturers like Watts, Zurn-Wilkins, Apollo, and Febco, we can usually clean valve seats, replace rubber discs, and re-test your assembly during the same visit.
Fairfax County Compliance Handled Without Friction
“I received an annual compliance letter from Fairfax County and had no idea who to call. Backflow Services Done Right arrived right on schedule, tested my sprinkler preventer in under 40 minutes, and sent the report directly to the county portal before driving away. Seamless experience.”
Homeowner in Fairfax, VA
Essential Partner for Our Commercial Properties
“Managing multiple retail spaces across Arlington means tracking half a dozen backflow deadlines. Their team handles our annual testing schedule, works during our off-hours so retail water is never disrupted, and keeps our documentation current. Reliable and professional.”
Commercial Facility Manager in Arlington, VA
Quick Repair and Same-Day Passing Test
“Our HOA pool house backflow valve failed its initial spring startup test. The technician explained the issue clearly, replaced the worn internal rubber check valves from parts on his truck, and re-tested it immediately. Saved our neighborhood from a major opening delay.”
HOA Board Trustee in Alexandria, VA
Water authority reporting guidelines vary across our service region:

Regulated properties are assigned a mandatory testing month based on local tax map grid numbers. Annual test reports must be logged by an authorized vendor before the end of that assigned month. Review our Fairfax County backflow testing guide for local filing schedules.

The Arlington Department of Environmental Services monitors backflow compliance for commercial lines, irrigation meters, and multi-family structures, requiring prompt filing after test completion. See our Arlington backflow testing services page.

Properties with cross-connections must prove current certification annually to protect the historical water distribution grid. Explore our Alexandria backflow testing services.

Commercial properties, private schools, and public buildings require documented annual tests filed with local municipal utility offices.
Virginia state health regulations mandate that every testable backflow prevention assembly undergo certified testing at least once every 12 months. Testing is also legally required immediately following a new installation, after an assembly is relocated, or after any internal repair.
No. Virginia law requires that backflow testing be performed exclusively by an individual holding a current Backflow Prevention Assembly Tester certification from the Department of Professional and Occupational Regulation (DPOR). Our technicians hold individual DPOR certifications, and our business operates under Virginia Class A Contractor License #2705041764.
If your backflow preventer is installed on an exterior irrigation riser or within an outdoor ground vault with clear access, you do not need to be on-site. If your device is located inside a basement, utility room, or mechanical closet, an adult must provide property access.
Yes, but only for a brief window. We isolate the specific backflow assembly using shutoff valves for approximately 15 to 30 minutes to conduct the pressure differential tests. For commercial properties, we can schedule testing during off-hours to avoid disrupting business operations.
We handle all reporting for you. As an authorized backflow vendor, Backflow Services Done Right prepares and submits official compliance reports directly to Fairfax Water, Arlington County, AlexRenew, and other local purveyors. You receive a digital copy for your own records.
Avoid administrative penalties, water shutoff notices, and water contamination risks. Partner with a local company backed by nearly a century of continuous plumbing service in Northern Virginia.
(703) 250-4200
(703) 524-1250
11608 Fairfax Station Rd, Fairfax Station, VA 22039
Providing reliable, code-compliant backflow Certified services for homes and businesses across Northern Virginia.